Instructions for Connecting Piping to Indoor Unit
Align the center of the two pipes
that you will connect.
Tighten the flare nut as tightly as possible by hand.
Using a spanner, grip the nut on the unit tubing.
While firmly gripping the nut on the unit tubing, use a
torque wrench to tighten the flare nut according to the
torque values in the Torque Requirements table below.
Loosen the flaring nut slightly, then tighten again.
2
TORQUE REQUIREMENTS
Outer Diameter of Pipe(mm) Tightening Torque(N•m) Flare dimension(B)(mm)
Flare shape
Ø 6.35 (Ø 1/4”) 8.4~8.7 (0.33~0.34”)
13.2~13.5 (0.52~0.53”)
16.2~16.5 (0.64~0.65”)
19.2~19.7 (0.76~0.78”)
23.2~23.7 (0.91~0.93”)
18~20(180~200kgf.cm)
32~39(320~390kgf.cm)
49~59(490~590kgf.cm)
57~71(570~710kgf.cm)
67~101(670~1010kgf.cm)
Ø 9.52 (Ø 3/8”)
Ø 12.7 (Ø 1/2”)
Ø 16 ( Ø 5/8”)
Ø 3/4”)
Ø 19 (
DO NOT USE EXCESSIVE TORQUE
Excessive force can break the nut or damage the refrigerant piping. You must not exceed
torque requirements shown in the table above.
R0.4~0.8
45
°
±
2
90
°
±
4
B
37
Connecting Piping to Indoor Unit
Indoor unit tubing Flare nut Pipe
Torque
wrench
Indoor unit tubing
Spanner (fixed)
Connection pipe
Flare nut
Step 1: Step 2:
●
●
●
●