C5 1-3 SERIES HOLDING & PROOFING CABINETS — INSTRUCTIONS FOR USE
10
www.metro.com
L01-430
REV W 01/22
OPERATING INSTRUCTIONS
Power-Up & Pre-Heat
YOUR C5 1 SERIES OR 3 SERIES CABINET MAY BE EQUIPPED WITH SEVERAL DIFFERENT MODULES:
C5 1 SERIES C5 3 SERIES
COMBINATION PROOF & HOLD MODULE COMBINATION PROOF & HOLD MODULE
HOLDING MODULE HOLDING MODULE
PROOFING MODULE MOISTURE HOLDING MODULE
A. Refer to the data plate located near the power cord for the electrical specifications of cabinet as shown on page 5.
With the POWER switch OFF, plug the cord into the appropriate rated, grounded receptacle.
Cabinets rated at 120V 1440W must be plugged into either a 15 amp or 20 amp 125VAC receptacle.
Cabinets rated at 120V 2000W must be plugged into a 20 amp 125VAC receptacle.
Cabinets rated at 220-240V must be plugged into a 15 amp 250VAC receptacle.
B. With POWER switch OFF, plug into a grounded receptacle.
C. Fill stainless water pan to
1
/
2
" from the top with clean HOT tap water for Proofing, Combination, and Moisture holding
modules. Check water level every 3 hours (2 hours when Proofing) and refill with clean HOT tap water as necessary.
Proofing and Moisture Holding Module require water pan to be filled if moisture control is turned on.
HOLDING INSTRUCTIONS (Combo, Holding & Moisture Holding)
1. Set Combination Module switch to HOLD.
2. Set POWER switch to the ON position.
3. Set TEMPERATURE control to 10.
4. On Moisture Holding only: Set MOISTURE
control to 10.
5. Pre-heat cabinet until desired temperature is reached
(typical heat-up time from 72°F (22°C) ambient to
160°F (71°C) is approximately 45 minutes).
6. Re-set TEMPERATURE control and adjust as necessary
to reach the desired temperature (setting 6-8 typical
for 150°F (66°C) to 160°F (71°C)). Power indicator light
will turn on and off as the heat thermostat cycles.
7. On Moisture Holding only: Adjust MOISTURE
control to desired level (10 being highest level,
1 lowest level, OFF being no heat to the water).
The indicator lights will turn on and off as the
heat and moisture thermostats cycle.
PROOFING INSTRUCTIONS (Combo & Proong)
1. Set Combination Module switch to PROOF.
2. Set POWER switch to the ON position.
3. Set TEMPERATURE control to 2.
4. Set MOISTURE control to 10.
5. Pre-heat cabinet until desired temperature and humidity
is reached (typical heat-up time from 72°F (22°C)
ambient to 95°F (35°C) and 95% relative humidity is
approximately 30 minutes).
6. Adjust settings as necessary to reach the desired
temperature and humidity levels. Power indicator lights
will turn on and off as the heat and moisture
thermostats cycle.
7. Adjust MOISTURE control to desired level (10 being
highest level, 1 lowest level, OFF being no heat to the
water). The indicator lights will turn on and off as
the heat and moisture thermostats cycle.
When the power switch is on, the blower is always energized, circulating air, and the digital thermometer is always
displaying the cabinet temperature. When the thermostat senses heat is required, the appropriate indicator will light and
the heater element will begin to produce heat.
At the end of the operating day, it is not necessary to disrupt the temperature setting to turn the cabinet off. By
switching the power switch off, the cabinet is no longer operating. When resuming operations, switch the power on and
the cabinet will attain the previous temperature and moisture levels.
Moisture Holding
Module
MOISTURE
HOLDING
MOISTURE
HOLDING
Moisture Holding
Module
Figures Shown in °F

Bekijk gratis de handleiding van Metro C533-CLFC-U, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkMetro
ModelC533-CLFC-U
CategorieNiet gecategoriseerd
TaalNederlands
Grootte5137 MB