Dual assignment instructions (long button press)
The Axxess interface has the capability to assign (2) functions to a single button, except Volume-
Up and Volume-Down. Follow the steps below to program the button(s) to the desired setting.
Note: Seek-Up and Seek-Down come pre-programmed as Preset-Up and Preset-Down for a
long button press.
1. Turn the key to ignition but do not start the vehicle.
2. Press and hold the desired steering wheel control button for (10) seconds, or until the LED
flashes rapidly. At this point release the button; the LED will then go solid.
3. Press and release the Volume-Up button the number of times corresponding to the new
button number selected. Refer to the Dual Assignment Legend. The LED will flash rapidly
while the Volume-Up button is being pressed, and then go back to a solid LED once
released. Proceed to the next step once the Volume-Up button has been pressed the
desired number of times.
Caution: If more than (10) seconds elapses between pressing the Volume-Up button, this
procedure will abort, and the LED will go out.
4. Press the desired button to store it to memory. The LED will now go out indicating the new
information has been stored to memory.
Note: These steps must be repeated for each button desired to assign a dual assignment feature
to. To reset a button back to its default state, repeat Step 1, then press the Volume-Down button.
The LED will go out, and the dual assignment feature for that button
will be erased.
STEERING WHEEL CONTROL SETTINGS (CONT.)
Dual assignment legend
1. Not allowed
2. Not allowed
3. Seek-Up/Next
4. Seek-Down/Prev
5. Mode/Source
6. ATT/Mute
7. Preset-Up
8. Preset-Down
9. Power
10. Band
11. Play/Enter
12. PTT (Push to Talk)
13. On-Hook
14. Off-Hook
15. Fan-Up *
16. Fan-Down *
17. Temp-Up *
18. Temp-Down *
* Not applicable in this application
Resetting the Axxess interface
1. The Blue reset button is located inside the Axxess interface, between the two connectors.
The button is accessible outside the Axxess interface, no need to open the Axxess interface.
2. Press and hold the reset button for (2) seconds, then let go to reset the Axxess interface.
3. Refer to “Programming the Axxess Interface” from this point.