WARNING
Caution, risk of fire
Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer. The appliance shall be
stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating
electric heater.)
Do not pierce or burn.
Be aware that refrigerants may not contain an odour.
The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation-a warning
that the appliance shall be stored in a room without continuously operating open flames (for example an operating gas appliance) and ignition
sources (for example an operating electric heater).
The appliance shall be stored so as to prevent mechanical damage from occurring.
The compliance with national gas regulations shall be observed; Min applicable area of this
machine is 15m .
Please ensure that there are no obstacles in front of the machine, keep ventilation openings clear of obstruction.
Servicing shall be performed only as recommended by the manufacturer.
Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-
accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with an industry recognized assessment
specification.
Servicing s
hall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other
skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.
Before servicing the appliance
Checks to the area:
Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is
minimized. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system
Work procedure:
Work shall be undertaken under a controlled procedure so as to minimize the risk of a flammable gas or vapor being present while the work is
being performed.
General work area:
All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces
shall be avoided. The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by
control of flammable material.
Checking for presence of refrigerant:
The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially
flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. non-sparking,
adequately sealed or intrinsically safe.
smoking