INSTALLATION
Check the appliance is electrically safe when you have nished.
25
Location of Cooker
The cooker may be installed in a kitchen/kitchen diner but
NOT in a room containing a bath or shower.
This appliance is designed for domestic cooking only. Use for
any other purpose could invalidate any warranty or liability
claim.
Note: An appliance for use on LPG must not be installed
in a room or internal space below ground level, e.g. in a
basement.
Conversion
This appliance is supplied set for G20 20 mbar Cat II
2H3+
.
A conversion kit for another gas is available for the cooker.
If the appliance is to be converted to another gas we
recommend that this is carried out before installation.
n
We recommend an overpressure shut-o device or
pressure relief valve be used in any LPG installation
to prevent exposure of downstream ttings /
appliances to excessive pressure (over 75mbar) in
event of regulator failure.
After converting the appliance, please attach the Gas
Conversion sticker over the appropriate area of the data
badge – this will identify the gas type for which the appliance
is now set.
You will need the following equipment to complete the
cooker installation satisfactorily:
Stability bracket: If the cooker is to be supplied with gas
through a flexible hose, a stability bracket or chain must
be fitted. These are not supplied with the cooker but
are available at most builders’ merchants.
Gas pressure tester/manometer.
Flexible gas hose: Must be in accordance with the
relevant standards.
Multimeter (for electrical checks).
You will also need the following tools:
1. Steel tape measure
2. Cross-head screwdriver
3. Flat head screwdriver
4. Spirit level
5. 13mm spanner or socket wrench
6. 8 mm socket wrench or ring spanner
Checking the Parts:
5 pan supports Wok cradle
Grill pan & trivet Grill pan cradle
1 drop shelf 3 at shelves
1 telescopic shelf Oven Base Tray