Start charging process
The charging process can be started as soon as the charging
cable is connected to the infrastructure. Please also note the
documentation for your electric vehicle.
The self-test function of the device when switching on
checks all important parameters and only enables the
charge, if all test criteria are fulfilled.
In the case of temporary power failure, the charging pro-
cess will be automatically continued after the voltage is
restored.
Terminate charging process
Do not remove the plug, while the charging process is still
active.
f Terminate the charging process at your vehicle first.
Please note the documentation for your electric vehicle.
After use, re-attach the factory-mounted protective cap.
Wind the charging cable without kinks and store it properly
in your vehicle.
Please note cover page – image 2 and 5.
Please note cover page – image 3.
Note for plug / coupling type GB and type 1:
Press the release button of the charging
connector for unplugging.
Please note cover page – image 4.
Status of the light‑emitting diodes
LED 1 LED 2 State
flashes blue flashes blue
self-test
flashes orange flashes orange
flashes red flashes red
lights up
blue
off No vehicle connected.
flashes
blue
off Vehicle connected.
flashes
blue
flashes
blue
Charging process active.
off flashes
orange
Temperature too high.
1)
Charging will be continued with
reduced charging current.
off lights up
orange
Temperature critical.
1)
Charging will be stopped.
off flashes
red
Fault current occurred.
flashes
red
lights up
red
Fault current in domestic installation –
PE missing.
flashes
red
flashes
red
Critical error –
Device is damaged and must be
repaired by the manufacturer.
2)
lights up
red
lights up
red
Internal fault –
Temperature sensor defective
2)
,
FI test negative
2)
.
Reset fault massages:
f Disconnect the charging cable from the power supply by
removing the plug from the wall socket.
f Reinsert the device after 10 seconds.
1)
Errors due to temperature excess:
f Before the charging process, store the device at a place
with suited ambient temperature.
Please note the data plate on the housing.
2)
Faults which show a damage to the charging cable
are not reset.
These include:
Critical fault
Internal fault – temperature sensor defective
Internal fault – FI test negative
If the device shows damages, it must be checked by an
expert and be replaced, if necessary. In the case of repair,
please contact the specialist dealer / manufacturer.