13
Fault Cause Notes on troubleshooting
flashing red
Residual current circuit breaker (RCCB)
or circuit breaker (CB) in the charging
station has tripped.
Re-activate residual current circuit
breaker (RCCB) or circuit breaker (CB).
See Chapter 4.3.2 on page 9.
Error in the power supply to the
charging station (incorrect phase
sequence, missing phase, etc.).
Ask a qualified electrician to check the
power supply of the charging station.
Charging plug not interlocked. Acknowledge the fault with multi-
function button.
Disconnect charging cable and plug in
again.
Incorrect or faulty charging cable. Acknowledge the fault with multi-
function button.
Disconnect charging cable and plug in
again.
Check charging cable and replace if
necessary.
LED information bar does not light
up
No power supply to the charging
station.
Ask a qualified electrician to check the
charging station.
Control fuse in the charging station has
tripped.
Ask a qualified electrician to check the
charging station.
Charging plug cannot be removed
from the charging station.
Failure of the unlocking function. Ask a qualified electrician to check the
charging station.
I
f you cannot rectify the error or fault, ask a qualified electrician to check the charging station.