WALL configuration
Install the base elements as described in the previous section, then
attach the base to the motor housing in the opposite direction to the
table configuration, i.e. as shown in the figure. Fasten the hooks to the
wall with expansion plugs or another high-strength fastener, then hang
the motor body, assembled as described in the previous sections.
4. USE
The selector switch located along the cable starts blade rotation and consequently ventilation, which is
proportional to the number indicated by the index on the selector switch itself. Ventilation stops when “0” is
selected. Select the desired speed by gently turning the selector switch, which must not be turned too
aggressively.
To start the blade oscillation function, push down the oscillation control located at the rear on the upper part of
the motor body; pull the control upwards to stop it. It is advisable to start and stop oscillation with ventilation
off.
The motor unit can be tilted vertically to several pre-set positions, so that the flow can also be directed in this
direction: tilting can be done manually by grasping the motor unit and tilting it until a small click is heard. It is
advisable to use the other hand to grip the grille.
5. CARE AND MAINTENANCE
The product does not require any maintenance. Use a damp cloth for cleaning. Do not use any aggressive or
abrasive cleaning agents. It is imperative to disconnect the blade from the mains before cleaning. Do not use
compressed air to clean the blade, and in any case never try to help the blade rotate other than normal use of
the appliance. Wait until it is completely dry before reconnecting the appliance to the mains.
6. TROUBLESHOOTING
In the event that the appliance exhibits abnormal operating conditions other than that stated in Chapter 2
above, it is advisable to consult the following table for simple troubleshooting.
Problem
Possible cause
Probable solution
The fan does not start.
The electrical plug is disconnected
from the mains.
Plug the electrical plug into a
normal 10 A household socket.
The electrical socket to which the
fan is connected does not supply
electricity.
Check the
efficiency of the socket
by connecting another appliance
that is definitely working. If
necessary, contact an electrician.
Oscillation does not start.
Oscillation control is not fully
pressed.
Fully press down the control (7).
Oscillation does not
stop.
Oscillation control is not fully
released.
Fully release the control (7).
Fan is particularly noisy.
Parts are not fully assembled.
Review the assembly process,
tightening screws and bolts more
fully.
If the product shows malfunctions or anomalies other than those indicated, it is highly probable that the
problem cannot be solved independently. In this case, consult qualified technical personnel.

Bekijk gratis de handleiding van Melchioni MF 2412TRIO, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkMelchioni
ModelMF 2412TRIO
CategorieVentilator
TaalNederlands
Grootte5035 MB