Sealing Check
Ensure that the knobs on the control panel are closed and the hood
is open for sealing and gasket safety control.
Apply soap foam to the connection points. There will be foaming
here if there is a leak/leakage.
WARNING: Never use any lighters, matches, lit
cigarettes, or similar ammable materials when
checking for gas leakage.
Ventilation Of Room
The air needed for burning is received from room air and the gases
emitted are given directly in room. For safe operation of your prod-
uct, good room ventilation is a precondition. If no window or room
to be utilized for room ventilation is available, additional ventilation
should be installed. However, room has a door opening outside, it is
no needed to vent holes.
Room size Ventilating opening
Smaller than 5 m³ min. 100 cm²
Between 5 m³ - 10 m³ min. 50 cm²
Bigger than 10 m³ no need
In basement or cellar min. 65 cm²