observed to verify normal operation. If abnormal performance is observed, additional measures
may be necessary, such as reorienting or relocating the Mebby NOSE CLEAN Nasal Aspirator.
b. Over the frequency range 150 kHz to 80 MHz, eld strengths should be less than 3 V/m.
EMC TABLES
Recommended separation distances between portable and mobile RF
communications equipment and the
Mebby NOSE CLEAN Nasal Aspirator
The Mebby NOSE CLEAN Nasal Aspirator is intended for use in the electromagnetic environment
specied below. The customer or the user of the Mebby NOSE CLEAN Nasal Aspirator should
assure that it is used in such an environment.
Immunity
test
IEC 60601
test level
Com-
pliance
level
Electromagnetic
environmentguidance
Radiated RF
IEC 61000-
4-3
10 V/m
80 MHz to
2,5 GHz
10 V/m Portable and mobile RF communications equip-
ment should be used no closer to any part of the
Mebby NOSE CLEAN Nasal Aspirator, including
cables, than the recommended separation distance
calculated from the equation applicable to the fre-
quency of the transmitter.
Recommended separation distance:
d=1.2 √P
d=2 √P
d=1.2 √P 80MHz to 800MHz
d=2.3 √P 80MHz to 2.7GHz
where P is the maximum output power rating of the
transmitter in watts (W) according to the transmit-
ter manufacturer and d is the recommended sepa-
ration distance in metres (m).
Field strengths from xed RF transmitters, as deter-
mined by an electromagnetic site survey, should be
less than the compliance level in each frequency
range.
Interference may occur in the vicinity of equipment
marked with the following symbol:
NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is aected
by absorption and reection from structures, objects and people.
a. Field strengths from xed transmitters, such as base stations for radio (cellular/cordless) te-
lephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast
cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due
to xed RF transmitters, an electromagnetic site survey should be considered. If the measured
eld strength in the location in which the Mebby NOSE CLEAN Nasal Aspirator is used exceeds
the applicable RF compliance level above, the Mebby NOSE CLEAN Nasal Aspirator should be
The Mebby NOSE CLEAN Nasal Aspirator is intended fo use in anelectromagnetic en-
vironment in which radiated RF disturbances are controlled. The customer or the user
of the NS1 Nasal Aspirator can help prevent electromagnetic interference by main-
taining a minimum distance between portable and mobile RF communications equi-
pment (transmitters) and the Mebby NOSE CLEAN Nasal Aspirator as recommended
below, according to the maximum output power of the communications equipment.
Rated maxi-
mum
output power
of transmitter
W
Separation distance according to frequency of transmitter
fMHz
150 kHz to 80 MHz
d=1.2 √P
d=2 √P 80 MHz to 800 MHz
d=1.2 √P
800 MHz to 2.5 GHz
d=2.3 √P
0.01 0.12 0.2 0.12 0.23
0.1 0.38 0.63 0.19 0.73
1 1.2 2 1.2 2.3
10 3.8 6.32 3.8 7.3
100 12 20 12 23
For transmitters rated at a maximum output power not listed above, the recommen-
ded separation distance d in metres (m) can be estimated using the equation appli-
cable to the frequency of the transmitter, where P is the maximum output power
rating of the transmitter in watts (W) according to the transmitter manufacturer.
NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency
range applies.
NOTE 2 These guidelines may not apply in all situations.
Electromagnetic propagation is aected by absorption and reection from structu-
res, objects and people.