[EN] 2
Keep out of water: Never operate the air conditioner in pooled or standing water, as this may create a
risk of injury from electrical shock. Do not store or operate outdoors. If electrical wiring or components
become wet, thoroughly dry them before using the air conditioner. If in doubt do not use the air
conditioner and consult a qualied electrician or a Meaco approved engineer.
Keep air intakes clear: Do not clog or block the air intakes by placing the air conditioner too close to
curtains, walls or anything that will restrict the air inlet. Do not immerse or expose the air conditioner to
rain, moisture or any other liquid. Any of these actions may cause the air conditioner to overheat and
result in a re or electrical hazard.
Keep electrical components dry: Never allow water inside the air conditioner’s electrical
components. If these areas become wet for any reason, thoroughly dry them before using the air
conditioner. If in doubt, do not use the air conditioner and consult a qualied electrician or a Meaco
approved engineer.
The operator must make the operating instructions available for the user and make sure that the user
does understand the manual.
The MeacoCool Pro Series 12000 BTU, 12000CH BTU, 14000 BTU, 14000CH BTU, 16000 BTU and
16000CH BTU air conditioners use R290 refrigerant gas to comply with European Environmental
Directives. R290 is kinder to the environment and is part of attempts to reduce global warming as it
has a low greenhouse eect (GWP).
When using the MeacoCool Pro Series air conditioner you must take into account the following:
• This air conditioner uses about 240 grams of R290 refrigerant in the 12000 BTU and 12000CH BTU
model, 270 grams of R290 refrigerant in the 14000 BTU and 14000CH BTU model and 265 grams of
R290 refrigerant in the 16000 BTU and 16000CH BTU model which is ammable. Therefore, it is part
of a sealed system and must only be serviced by a trained Meaco engineer.
• Do not use or store this air conditioner in a room smaller than 5.2m² to prevent a re or explosion
hazard if there is a leak of refrigerant and the gas comes into contact with an ignition source.
• Do not use in a room with any continuous sources of ignition, for example open ames, gas res or
hobs, cigarettes or any other sources of ignition.
• If the air conditioner is installed, operated or stored in a non-ventilated area, then the room must be
designed to prevent the accumulation of refrigerant leaks resulting in a risk of re or explosion due to
ignition of the refrigerant caused by electric heaters, cookers, or other sources of ignition.
• R290 refrigerant gas is odourless.
• Do not puncture either during the air conditioners working life or after. At the end of life dispose of
following local recycling regulations.
• If there is any damage to the air conditioner then do not use it and contact Meaco or your retailer.
• As with all air conditioners, always keep upright and leave the air conditioner standing upright for 24
hours before using it upon receipt.