INSTRUCTION MANUAL FOR DISHWASHERS
Page 14 of 16
UK
Chap 7 SETTINGS
The following settings should only be configured by a qualified technician.
The parameters listed below can be set during installation of afterwards, accessing the settings menu as
follows:
Machine in standby with door open.
Press buttons 1 and 2 together (ON/OFF and SPECIAL PROGRAMME SELECTION) for 5 seconds
and enter the key KEY 12 (buttons 3 and 4 to change the parameter, 1 to confirm).
Then press button 1 (ON/OFF) repeatedly to scroll through the following headings, enabling and/or
changing them using buttons 3 and 4 (the modified parameter is memorised without being confirmed).
The list of parameters may vary according to the type of dishwasher.
Language
Language selection
Boiler Set
Boiler temperature settings for programmes. In the versions with atmospheric
boiler (rinse pump) there are different settings for each programme (b1 – b2
– b3)
Tank Set
Tub temperature regulation for programmes. Rinse pump versions have
different settings for each programme (t1 – t2 – t3)
ThermoStop
Enabling the Thermostop function, which guarantees the correct
rinse temperature.
Energy Saving
Enabling the Energy Saving function, which guarantees
energy savings when the dishwasher is on but not in use.
Manual Detergent
Manual operation of detergent doser
By setting ON, the suction pipe is automatically loaded.
The length of the pipe is predetermined according to the dishwasher model.
Manual Rinse Aid
Manual operation of rinse aid doser
By setting ON, the suction pipe is automatically loaded.
The length of the pipe is predetermined according to the dishwasher model.
Detergent Dose
Adjustment of detergent dosing time or quantity in g/L according to the model.
Rinse Aid Dose
Adjustment of rinse-aid dosing time or quantity in g/L according to the model.
Water Hardness
Water supply hardness setting, for machines with built-in water softener, set
according to measured water hardness.
External Softenr Cycles
Cycle counter setting and activation to enable the Service alert for an external
water softener.
The Service alert can be cancelled by holding pressed all 4 buttons with the
machine off and the door open.
Manual Rinse Pump
Manual operation of the rinse pump
Manual Drain
Manual operation of the drain pump
Autostart Enable
Automatic enabling of automatic starting
Cycle Counter
Cycle counter
Water Service Set
Setting of litres of autonomy for external water treatment equipment,
adjustment setting from 0 to 12000 litres in steps of 200.
The message Er 25 can be reset by simultaneously pressing all 4 buttons
from this menu.
Once all necessary parameters have been set, to exit and save any changes simply press and hold
button 1 for a few seconds until the display switches off.