7. CONNECTION AND OPERATION
WARNING: Carefully read the “SAFETY INFORMATION” before switching on the heater.
NOTE: If the room temperature is higher than the temperature set on the thermostat, the heater does not
go on.
►►►ROOM THERMOSTAT --MODEL 1-- (PIC. 1):
►►7.1. OPERATION:
►7.1.1. Connect the power cable of the room thermostat to the mains (PIC. 4).
►7.1.2. Connect the power cable of the heater to the room thermostat (PIC. 5).
►7.1.3. Turn on the heater and set the desired temperature by turning the knob (PIC. 6).
►►►ROOM THERMOSTAT --MODEL 2-- (PIC. 2):
►►7.2. OPERATION:
►7.2.1. Remove the plug connected to the heater and connect the room thermostat to the heater (PIC. 7).
►7.2.2. Turn on the heater and set the desired temperature by turning the knob (PIC. 6).
►►►DIGITAL ROOM THERMOSTAT --MODEL 3-- (PIC. 3):
►►7.3.1. THERMOSTAT SETTING:
This menu allows you to set and adjust the operating parameters of the room thermostat.
Access the menu as follows:
►Press the buttons “+” / “-” (D PIC. 8) simultaneously for a few seconds, and “C.O.S.t.“ will appear on the
display (A PIC. 8).
►Press “SET“ (C PIC. 8) to move around the menu, until the desired setting appears on the display (A
PIC. 8). Refer to the table below as a reference [press the buttons “+” / “-” (D PIC. 8) to set the correct
setting]:
PARAMETER PRESET DESCRIPTION
diFF 0,2 °C Sets the “ON/OFF“ dierential
tEnP °C Unit of measurement “°C” / “°F“
Ad.tE 0.2 °C Correction of the temperature probe
rY.OC 1 Type of probe (Correct setting 1)
►Press “SET“ (C PIC. 8) to conrm the setting.
►Press and hold “SET“ (C PIC. 8) for a few seconds to exit the menu.
►►7.3.2. OPERATION:
►Press “SET“ (C PIC. 8) to enter the temperature setting menu.
►Press the buttons “+” / “-” (D PIC. 8) to set the desired temperature.
►Press “SET“ (C PIC. 8) to conrm and exit the menu.
NOTE: During heater mode, the “FLAME (HEATING ON)” or “SNOW (COOLING ON)” (B PIC. 8) LEDs
light up to indicate the status of the room thermostat.
►►7.3.3. DISPLAY OF RECORDED TEMPERATURES:
►Pressing “+“ (D PIC. 8) displays the maximum temperature recorded.
►Pressing “-“ (D PIC. 8) displays the minimum temperature recorded.
NOTE: Reset the log by pressing and holding “+“ (D PIC. 8) for a few seconds and “CLEA“ will appear on
the display (A PIC. 8).