TROUBLE SHOOTING
Fault
Cause
Solution
L
ight on, but
motor doe
s not
w
ork
The bl
ades are blocked.
The c
apacitor is damaged.
Rep
lace capacitor.
The mot
or is damaged.
Rep
lace motor.
The in
ternal wiring of motor is cut off/
d
isconnected. An unpleasant smell
m
ay be produced.
Rep
lace motor.
Bot
h light and
motor do n
ot
w
ork
Apart from
the above mentioned, check the following:
Light damaged.
Replace lights.
Power
cord loose.
Conne
ct the wires as per the electric
diagram.
O
il leakage
O
utlet and the air ventilation entranc
e
are not t
ightly sealed.
T
ake down the outlet and seal with glue.
Lea
kage from the connection of
U
-shaped section and cover.
T
ake U-shaped section down and seal
w
ith soap or paint.
V
ibration
The bl
ade, if damaged, can cause
vi
brating.
Rep
lace the blade.
The mot
or is not tightly fastened.
Faste
n the motor tightly.
The c
ooker hood is not tightly fixed.
Fixed the
cooker hood tightly.
In
sufficient
s
uction
The di
stance between the cooker
hood and th
e cooker top is too large.
Read
just the distance.
T
oo much ventilation from open d
oors
or
windows.
Choo
se a new place to install the
app
liance or close some doors / windows
.
The
ma
chine
i
nclines
The fixin
g screws are not tight
enough.
T
ighten the fixing screw and make it
hori
zontal.
The hang
ing screws are not tight
enough
T
ighten the hanging screw and make it
hori
zontal.
02 03 04
05 06 07 08
09 10 11
12