6 VC-Strip™ Family Safety and Installation Guide
Each time you reach (a) the maximum permitted number of modules in one chain, or (b) the PSU
output’s maximum power rating – whichever you reach first – you must create a new chain of modules
that is connected to a new 48 VDC power output.
• If you supply a chain of VC-Strip modules with DC power from a generic 48 VDC external PSU and the
DC output used does not have constant overcurrent protection that limits current to 8 A, install an inline
fuseholder with a 7.5 A or 8 A fuse on the circuit that you connect to that DC output.
• Provide a means of locking out AC mains power that allows power to the installation to be shut down and
made impossible to reapply, even accidentally, during work on the installation.
• Shut down power to the installation during service and when it is not in use.
• Before applying power to the installation, check that all power distribution equipment and cables are in
perfect condition and rated for the current requirements of all connected devices.
• Isolate the installation from power immediately if any product, power cable or power plug is in any way
damaged, defective or wet, or if it shows signs of overheating.
• Do not expose the VC-Strip to rain or moisture.
PROTECTION FROM BURNS AND FIRE
• The VC-Strip is cooled by convection. Provide free airflow and a minimum clearance of 10 mm (0.4 in.)
around modules. Monitor the VC-Strip’s temperature by calling up temperature readouts on the P3
System Controller. If any of the product temperature readouts exceed the levels given in Table 1 on page
5, provide fan assistance to give active cooling to the installation.
• Do not operate the VC-Strip if the ambient temperature (Ta) exceeds 45° C (113° F).
• Do not modify the VC-Strip in any way not described in this manual or install other than genuine Martin
parts. Use only accessories approved by Martin.
PROTECTION FROM INJURY
• When installing the VC-Strip above ground level, ensure that the installation hardware and supporting
structure can hold at least 10 times the weight of all the devices they support.
• In an overhead installation or where the VC-Strip may cause injury if it falls:
- block access below the work area and work from a stable platform whenever installing, servicing or
moving the VC-Strip, and
- as soon as work is completed, check that all hardware and components are securely in place and
fastened to supporting structures.
Type of VC-Strip module in
chain
Maximum permitted
number of modules in one
chain
Wattage per VC-Strip
module
VC-Strip 32x1 15 45 8 W
VC-Strip 16x1 15 63 4 W
VC-Strip 16x1 25 45 8 W
VC-Strip 8x1 25 63 4 W
VC-Strip 16x1 30 45 8 W
VC-Strip 8x1 30 63 4 W
VC-Strip 8x1 60 63 4 W
VC-Strip 4x1 60 63 2 W
Table 3: Maximum number of VC-Strip modules per 48 VDC external PSU
Bekijk gratis de handleiding van Martin VC-Strip, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Martin |
Model | VC-Strip |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 3742 MB |