Martin VC-Strip handleiding
Handleiding
Je bekijkt pagina 26 van 36

26 VC-Strip™ Family Safety and Installation Guide
Troubleshooting
Problem Probable cause(s) Remedy
Control is lost and pressing
control button causes VC-Strip
to show constant or flashing red
status indication.
Error has occurred.
Check that system is correctly connected, set up
and running.
Hold control button pressed in until it turns blue,
then release, to reboot VC-Strip.
Restart P3 or DMX controller.
Product seems completely
dead.
Product has gone into thermal protection
shutdown.
Check product temperature readouts on P3 system
controller. Reduce ambient temperature by
providing ventilation or fan cooling, for example.
No DC power to product. Check 48 VDC power supply and cables
Internal fault.
Disconnect from power. Do not attempt repairs
yourself. Contact Martin Service or an authorized
Martin service partner for assistance.
VC-Strip does not display as
intended.
Bad 48 VDC power transmission.
Inspect connections and cables. Correct poor
connections. Repair or replace damaged cables.
Bad data transmission.
Inspect connections and cables. Correct poor
connections. Repair or replace damaged cables.
Incorrect mapping or addressing of products. Check product address and controller settings.
Product in installation is defective and is
disturbing data transmission.
Substitute known good products one at a time until
normal operation is regained. Have faulty product
serviced by Martin Service.
Table 8: Troubleshooting
Bekijk gratis de handleiding van Martin VC-Strip, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Martin |
Model | VC-Strip |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 3742 MB |