Martin VC-Grid 15 handleiding

32 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 29 van 32
Specifications 29
VC-Grid 16x16 15 RGB
Peak power consumption (at full intensity, full white) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 W
Peak current draw per module (at full intensity, full white) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.3 A
Typical power consumption per module (with typical video content) . . . . . . . . . . . . . . . . . . . . . . . . . . .20 W
Typical current draw per module (with typical video content). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.4 A
VC-Grid 8x8 25 RGB
Peak power consumption (at full intensity, full white) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 W
Peak current draw per module (at full intensity, full white) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.7 A
Typical power consumption per module (with typical video content) . . . . . . . . . . . . . . . . . . . . . . . . . . .10 W
Typical current draw per module (with typical video content). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.2 A
VC-Grid 8x8 30 RGB
Peak power consumption (at full intensity, full white) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 W
Peak current draw per module (at full intensity, full white) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.7 A
Typical power consumption per module (with typical video content) . . . . . . . . . . . . . . . . . . . . . . . . . . .10 W
Typical current draw per module (with typical video content). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.2 A
VC-Grid 8x8 60 RGB
Peak power consumption (at full intensity, full white) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 W
Peak current draw per module (at full intensity, full white) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.7 A
Typical power consumption per module (with typical video content) . . . . . . . . . . . . . . . . . . . . . . . . . . .10 W
Typical current draw per module (with typical video content). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.2 A
VC-Grid 4x4 60 RGB
Peak power consumption (at full intensity, full white) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 W
Peak current draw per module (at full intensity, full white) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.2 A
Typical power consumption per module (with typical video content) . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 W
Typical current draw per module (with typical video content). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.1 A
Figures are per module and allow for cable in a chain with a total hybrid cable length of 50 m.
Figures for typical video content are indicative only and will vary. Peak figures must always be used for
safety calculations.
Thermal
Cooling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Convection
Maximum ambient temperature (Ta max.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45° C (113° F)
Minimum ambient temperature (Ta min.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -20° C (-4° F)
VC-Grid 16x16 15 RGB
Peak heat dissipation (calculated, at full intensity, full white). . . . . . . . . . . . . . . . . . . . . . . . . . . 206 BTU/hr.
Typical heat dissipation (calculated, with typical video content) . . . . . . . . . . . . . . . . . . . . . . . . . 68 BTU/hr.
VC-Grid 8x8 25 RGB
Peak heat dissipation (calculated, at full intensity, full white). . . . . . . . . . . . . . . . . . . . . . . . . . . 103 BTU/hr.
Typical heat dissipation (calculated, with typical video content) . . . . . . . . . . . . . . . . . . . . . . . . . 34 BTU/hr.
VC-Grid 8x8 30 RGB
Peak heat dissipation (calculated, at full intensity, full white). . . . . . . . . . . . . . . . . . . . . . . . . . . 103 BTU/hr.
Typical heat dissipation (calculated, with typical video content) . . . . . . . . . . . . . . . . . . . . . . . . . 34 BTU/hr.
VC-Grid 8x8 60 RGB
Peak heat dissipation (calculated, at full intensity, full white). . . . . . . . . . . . . . . . . . . . . . . . . . . 103 BTU/hr.
Typical heat dissipation (calculated, with typical video content) . . . . . . . . . . . . . . . . . . . . . . . . . 34 BTU/hr.
VC-Grid 4x4 60 RGB
Peak heat dissipation (calculated, at full intensity, full white). . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 BTU/hr.
Typical heat dissipation (calculated, with typical video content) . . . . . . . . . . . . . . . . . . . . . . . . . 11 BTU/hr.
Figure for typical video content is indicative only and will vary

Bekijk gratis de handleiding van Martin VC-Grid 15, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkMartin
ModelVC-Grid 15
CategorieNiet gecategoriseerd
TaalNederlands
Grootte1816 MB