RUSH™ Scanner 1 LED User Manual 39
Symptom Potential cause Remedies
Fixture does not
respond to DMX
control.
Fault in the DMX
network due to
connector or cable
damaged, or
incorrect DMX
addressing, or
potential interference
from proximity to a high
voltage installation.
Check that the fixture DMX
LED is on, and if not, check
all DMX cables and
connections to ensure the
integrity of the physical link.
Ensure that the DMX link is
terminated.
Check that all devices on
the DMX link use standard
DMX polarity.
Ensure that the fixture is
set to the correct DMX
address, one that matches
that set on the DMX control
device.
Check the pins on the
connectors from the
previous fixture on the
DMX link.
Try to control the fixture
with another DMX control
device.
Move the fixture if it is
being operated very close
to an unshielded high-
voltage installation.