Martin RUSH Scanner 1 LED handleiding
Handleiding
Je bekijkt pagina 17 van 48

RUSH™ Scanner 1 LED User Manual 17
The fixture has an auto-ranging power supply that accepts AC mains power at
100-240 V at 50/60 Hz. Do not apply AC mains power at any other voltage or
frequency to the fixture.
Linking fixtures to power in a chain
If you obtain a 14 AWG or 1.5 mm
2
power input cable and 14 AWG or 1.5 mm
2
throughput cables from Martin™ (see ‘Accessories’ on page 42), you can relay
mains power from one fixture to another by connecting fixtures to power in a
linked daisy-chain, MAINS OUT throughput socket to MAINS IN input socket.
Using 14 AWG or 1.5 mm
2
cables from Martin™, you can link:
• Maximum eight (8) RUSH™ Scanner 1 LED fixtures in total at
100-120 V, or
• Maximum sixteen (16) RUSH™ Scanner 1 LED fixturesin total at
200-240 V.
If you install a power plug on the 14 AWG / 1.5 mm
2
power input cable, install
a grounding type (earthed) plug with integral cable grip that is rated minimum
16 A, 250 V.