RCP-PLUS User Manual
7.8 Adv Advanced Functions Page
Flip–Presstoipormirror,pressagaintocancel
Infrared – On most cameras this is simply black & white mode
Save Current Camera–Savecurrentcamerasettingtoanamedprole
Step 1. Press Yes
Step 2. Touch a check box
Step 3. Press Save
Step 4. Enter a name using Left & Right knobs
Step 5. Press Accept
Asavedprolemayberecalledwhenassigninganewcameratoabutton.
(See section 3 or 5 Assigning Cameras).
AnexistingProlemaybeLoadedtothecameraorSavedtoanewProle.
Cam Fcty Reset – This triggers a Factory Reset to the connected camera (not the RCP). Careful!
Admin – Administration setting special functions
Basic Mode – Limits RCP panel to only essential functions
Step 1. Enter a 4-digit Pass code using knobs and press Lock.Asimpliedpageappearsallowingonly
exposureadjustments
Step 2.Toreturntonormalfunction,pressUnlock,enterthePasscode,pressUnlock.
Factory Reset–Thisclearsallsettingsandallcameraassignments.ItdoesnoterasesavedProlesand
does not change the IP address.
Sync Camera(s) –Sync(match)camerastothecurrentRCPadjustments.
Baud Rate – For RS485 connections only.
RCP-PLUS is designed to work under adverse conditions and to be simple to implement.
Key features:
Simple,two-wirebalancedconnections(likebalancedaudio).Groundwireisnotrequired.
Multipledevicescanbeconnectedacrossthesamepairofwires.Thereisnormallynoneedforhubs,
activerepeaters,etc.
Thepreferredwiretypeissimpletwistedpair.Doorbellwire,apairinsideCAT5/6cable,etc.
Shielded wire is OK but attaching the shield at only one end is best practice. This is especially true when
camerasarepoweredfromadifferentsourcethanthecontrollerwhichcouldleadtoACcurrentowing
through the shield.
Speakerwire,ACwireisnotrecommendedduetonotwist.Twistingrejectsinterferencewhichbecomes
important for long wires.
Whilemanydevicescanbeconnectedatonce,theuseofViscaprotocollimitsthenumberofdevices
(cameras) to 7.
RS485connectionsareusuallylabeled“+”and“-“.Thisdoesnotindicatepower,onlydatapolaritysoitis
safetoconnectwiresbackwards,theysimplywon’tworkthatway.
MarshallMiniatureandCompactcameramodelsfollowtheruleof“plus”to“plus”and“minus”to
“minus”.Thatis,theconnectionmarked+atthecamerashouldgototheconnectionmarked+at
the controller.
The most common reason a camera does not respond to the controller is that the Visca ID # in the
camera does not match the Visca ID # set in the controller.
The second most common reason is that the wire polarity is reversed. Some 3rd party cameras follow
a + to – rule which can be confusing. This is why simply swapping the connections at one end of the wire
is worth trying when an RS485 system does not work.
Ifonecameraonastringisconnectedinreverse,itwillstopalldevicesonthestringfrom
communicating.Itisbesttotestwithjustonecamerabeforeattachingtherestofthecamerastoastring.
Several Baud rates (data speed) are selectable with RS485. All devices on a string must be set to the
samerate.Thedefaultvalueisalways9600.ThereisnorealadvantagetousinghigherBaudrates
sincecameracontrolinformationisverysmallandundemanding.Infact,ahigherBaudratereduces
reliability over long wire runs.
AcommonquestioniswhetherRS485,RS422andRS232canbeconnectedtogether.RS485andRS232
arenotcompatiblewithoutaconverterand,eventhen,theymaynotworktogether.Somedevicesusing
RS422 will work with RS485. Refer to the manufacturer of those devices for details.
TwocontrollerscanoftenoperateonthesameRS485system.TheRS485specicationstatesthatthis
ispossible.However,ViscaprotocolassumesacontrollerhasID#0,whichleavesID#1-7forcameras.
Conictingmayoccurwhenusing3rdpartycontrollers.
Chapter 8: Tips and Best Practices for RS485 Connections