Makita DX01 handleiding

48 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 7 van 48
7
CAUTION:
Wear respiratory protection when emptying the dust container.
Do not touch the lter section when cleaning it.
Do not use a brush or air duster to clean the lter section. Using a brush or compressed air may damage the lter.
1. Before removing the dust container from the attachment, hold the power tool horizontally. (Fig. 5)
2. Press the dust container release button and with the button depressed pivot it on the lower side axis.
3. Remove the dust container from the attachment. (Fig. 6)
4. To open the dust container, raise the lever lightly and then pivot the transparent section. (Fig. 7)
5. Empty the dust container by tapping it lightly.
Be careful not to let out excessive dust into the air.
6. Remount the dust container in place on the attachment.
MAINTENANCE
WARNING:
Always be sure that the tool is switched o󰀨 and battery cartridge is removed before attempting to perform inspection
or maintenance.
NOTE:
Do not use water, oil, grease, detergent or cleaning agents.
Never use gasoline, benzine, thinner, alcohol or the like. Discoloration, deformation or cracks may result.
Cleaning of the attachment
Clean the attachment using only a dry rug and a dry brush.
Wear respiratory protection when cleaning.
Replacing the lter
Check the lter regularly for damage and if damaged, replace the old lter with a new one.
To replace the lter, follow the procedure below. (Fig. 8)
1. Press the dust container release button and with the button depressed pivot it on the lower side axis.
2. Remove the dust container from the attachment. (Fig. 9)
3. Pry up the lter cover on the dust container using a slotted bit screwdriver to be inserted into the slit. (Fig. 10)
4. Pull the old lter away from the dust container by hand. (Fig. 11)
5. Put a new lter in the original position. (Fig. 12)
6. Snap the lter cover on the dust container. (Fig. 13)
7. Remount the dust container in place on the attachment.
Replacing the sealing cap
Replace a sealing cap at regular intervals as a worn or damaged sealing cap may a󰀨ect the suction performance.
1. Insert a at-blade screwdriver, with its at surfaces vertical, into one of the release holes placed on the sides of the
nozzle head. Tilt the at-blade screwdriver at an angle to squeeze and pop the cube hook of the sealing cap out
of the molded receptacle. Then peel the rubber edges of the sealing cap away from the rims of the nozzle head
opening. (Fig. 14)
2. Set one of cube hooks of a renewed sealing cap into the molded receptacle in the nozzle head with a recessed
surface of the sealing cap facing forwards. (Fig. 15)
3. Place the other hook into the receptacle on the opposite side of the nozzle head, while repositioning the sealing cap
to t nely to the nozzle head. (Fig. 16)
4. Gently lay the rubber edges of the sealing cap down over the rims of the nozzle head opening from bottom to top.
(Fig. 17)
TROUBLESHOOTING
Fault Possible cause Remedy
Unusual dust emission
The dust container is full. Emptying the dust container.
The sealing cap is worn or
damaged.
Replace the sealing cap.

Bekijk gratis de handleiding van Makita DX01, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkMakita
ModelDX01
CategorieNiet gecategoriseerd
TaalNederlands
Grootte5346 MB