Makita BCV02 handleiding

100 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 5 van 100
5
Abnormal indications during use
The BCV02 indicates various states using the remaining battery capacity indication.
Indicator lamps
Indication contents
: On : Off
: Blinking
Battery 1 Battery 2
The BCV02 may have malfunctioned.
The protective function operated.
The protective function operated.
Charge the battery.
The BCV02 detected an abnormally high
voltage.
1. BCV02 malfunction
When the three indicator lamps for Battery 1 and the three indicator lamps for Battery 2 light alternately, the BCV02
may have malfunctioned. Contact your Makita dealer or nearest Makita Sales Center to request inspection and/or
repair.
2.
BCV02 protective function
When a product is used continuously at a high load, the motor may stop automatically. This is due to the BCV02’s
protective function, and is not a malfunction. If the product does not operate even when the product switches are
operated, stop use, disconnect the product and batteries from the BCV02, and let the BCV02 cool down.
3. Battery protective function
The batteries have an internal protective function that automatically stops power output in order to extend the battery
life. When the following states occur during product use, the motor stops automatically, but this is due to the battery’s
protective function, and is not a malfunction.
When the battery temperature rises above a certain level, the motor stops automatically, and remains stopped even
when the switches are operated. In these cases, stop battery use, remove the batteries from the BCV02, and allow
the batteries to cool or charge the batteries.
When the battery capacity becomes low, the product’s motor stops automatically. If the product does not operate
even when the switches are operated, remove the batteries from the BCV02 and charge the batteries.
4. BCV02 abnormally high voltage detection
When the BCV02 detects an abnormally high battery voltage, the motor stops automatically. This is due to the
BCV02’s protective function, and is not a malfunction. In these cases, the motor remains stopped even when the
switches are operated.
Remove the batteries from the BCV02, and use different batteries with normal voltage.
NOTE:
When the product stops automatically without any BCV02 indication
When the product enters an overload state, power output stops automatically in order to extend the battery life. This
is due to the battery’s protective function, and is not a malfunction. In addition, in these cases the BCV02 does not
indicate anything, but this is not a malfunction. When this happens, release the switch, and remove the cause of the
overload. The product can then be used again by operating the switch again.

Bekijk gratis de handleiding van Makita BCV02, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkMakita
ModelBCV02
CategorieNiet gecategoriseerd
TaalNederlands
Grootte9067 MB