F-2
DIAGRAMS
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted
inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. Give the equipment code number.
A.03
INPUT POWER 230V/1PH/50Hz
3
BK
L
N
1
3
5
1
SET AT
5.75 A
4-6.3A
STOP START
2
GND
GND
2
4
6
L
BK
N
4
3X16AWG
3
START
CAPACITOR
FAN MOTOR
N
L
GND
MOTOR
230VAC, 4.7A,
1PH, 50Hz, 1HP
N
L
Z2
U2 V2
U1
V1
Z1
ITEM
PART NO.
DESCRIPTION
QTY
1 FC0308000680 16AWG BLACK WIRE
1
2
FC0328260100
4-6.3A MOTOR PROTECTION CIRCUIT BREAKER
1
3
FC0342050170 CABLE GLAND OF METRIC THREAD - M25 (BLACK)
2
4
FC0802060020
HOUSING MPS
1
MOTOR STARTER PRISM 2400, 230V, 1ph, 50Hz, 1HP
PRISM
®
WALL MOUNT