E-2
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Lincoln Authorized Service Facility for technical troubleshooting assistance before you proceed.
WWW.LINCOLNELECTRIC.COM/LOCATOR
PROBLEM
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED COURSE OF ACTION
Faulty Filter Maintenance
Indicator. Indicator does not
indicate saturation level of
pre-lter and/or LongLife
lter cartridge.
Blocked indicator tubes. Clean tubes with compressed air.
Indicator leaking. Replace Filter Maintenance Indicator.
Poor suction.
Prism Wall Mount (/HE) does
not function properly.
Outlet(s) blocked. Remove obstructions from the outlet opening(s) and/or
connected ductwork.
LongLife lter cartridge clogged (check lter
maintenance indicator - See Figure B.1).
Remove obstructions from the outlet opening(s) and/or
connected ductwork.
Pre-Filter clogged. Clean (See Periodic Maintenance) or replace (See Pre-
Filter) the pre-lter.
Dust or smoke coming out of
the outlet opening(s).
Pollution of the facility.
LongLife lter cartridge damaged. Replace LongLife lter cartridge (See LongLife Filter
Cartridge).
Sealing on LongLife lter cartridge damaged. Replace LongLife lter cartridge (See LongLife Filter
Cartridge).
Dust or smoke coming out of
the inlet connection(s).
Pollution of the facility.
Outlet(s) blocked. Remove obstructions from the outlet opening(s) and/or
connected ductwork.
LongLife lter cartridge clogged (check lter
maintenance indicator - See Figure B.1).
Replace LongLife lter cartridge (See LongLife Filter
Cartridge).
Pre-Filter clogged. Clean (See Periodic Maintenance) or replace (See Pre-
Filter) the pre-lter.
Non-return valve(s) installed incorrectly. Install non-return valve(s) correctly.
Dust or smoke coming out of
one arm (Dual Arm versions
only). Pollution of the facility.
Related non-return valve installed incorrectly. Install non-return valve correctly.
Related non-return valve damaged. Replace non-return valve.
Dust or smoke coming out of
bottom housing. Pollution of
the facility.
Cracks or holes in bottom housing. Replace bottom housing.
PRISM
®