18 INSTALLATION
c 1/2" adapter
d Gas flow into range
e Flex connector (6 ft. max.)
f Gas shut-off valve
g 1/2" adapter
h 1/2" or 3/4" gas pipe
Pressure Regulator Position
a Pressure regulator
Adjusting Air Shutters (for LP
Conversions)
The range comes from the factory with the air
shutters adjusted for proper air flow for natural
gas. If converted to LP, follow the instructions
provided in the conversion kit to properly adjust
the air shutters. LP conversion must be performed
by a qualified technician.
Connecting Electricity
Electrical Requirements
120 Volt, 60 Hz, properly grounded dedicated
circuit protected by a 15 or 20 Amp circuit breaker,
or slow blow fuse.
If an external electrical source is utilized, the
appliance, when installed, must be electrically
grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical
Code, NFPA70 or the Canadian Electric Code, CSA
C22.1-02.
Grounding
WARNING
For personal safety, this appliance must be
properly grounded.
This appliance is equipped with a three-prong
groundling plug for your protection against
shock hazard and should be plugged directly
into a properly grounded receptacle.
Do not cut or remove the groundling prong from
this plug.
The customer should have the wall receptacle
and circuit checked by a qualified electrician to
make sure the receptacle is properly grounded.
The power cord of this appliance is equipped
with a 3-prong (grounding) plug which mates
with a standard 3-prong grounding wall
receptacle to minimize the possibility of electric
shock hazard from this appliance.
Where a standard two-prong wall receptacle is
encountered, it is the personal responsibility and
obligation of the customer to have it replaced
with a properly grounded three-prong wall
receptacle.
Ensure proper ground
a exists before use.
Do not use an adapter plug. Disconnecting of
the power cord places undue strain on the
adapter and leads to eventual failure of the
adapter ground terminal.
Surface Burners
Assembling the Surface Burners
CAUTION
Do not operate the burners without all parts in
place.
1 Place the burner caps and heads on the
cooktop.
There is one small, one medium, one large,
one oval (center), and one extra large
burner head and cap.
2 Make sure that the caps and heads are placed
in the correct locations.