5IMPORTANT SAFETY INSTRUCTIONS
ENGLISH
• Installation
- Contact an authorized service center when installing or relocating the air conditioner.
- Do not install the air conditioner on an unstable surface or in a place where there is danger of it falling.
• Operation
- Do not modify or extend the power cable. Scratches or peeling insulation on the power cables may
result in fire or electric shock, and should be replaced.
- Make sure that the power cable is neither dirty, loose, nor broken.
• The refrigerant and insulation blowing gas used in the appliance require special disposal procedures.
• Consult a service agent or a similarly qualified person before disposing of them.
• This appliance is not intended for the purposes of cooling INFORMATION TECHNOLOGY EQUIPMENT.
• Qualification of workers
The manual shall contain specific information about the required qualification of the working personnel
for maintenance, service and repair operations. Every working procedure that affects safety means shall
only be carried out by qualified person by manufacturer. Examples of such work procedures are as
follows:
- breaking into the refrigerating circuit;
- opening of sealed components;
- opening of ventilated enclosures.
• Ventilated area
Ensure that the area is open and adequately ventilated before accessing the system or performing high-
temperature work.
A certain level of ventilation must be maintained for the duration of the work.
Ventilation should be such that any refrigerant emitted is safely dispersed and preferably moistened into
the outside atmosphere.
• Cabling
Check that the cable is not subject to wear, corrosion, excessive pressure, vibration, sharp edges, or
other adverse environmental influences. When checking, you should also take into account the effects of
aging or continuous vibration of ignition sources such as compressors or fans.
• Detection of flammable refrigerants
Under no circumstances should potential ignition sources be used to detect or detect refrigerant leaks.
Do not use halide lamps (or other detectors that use fine salts).
• Leak detection methods
The following leak detection methods are deemed acceptable for all refrigerant systems.
Electronic leak detectors may be used to detect refrigerant leaks but, in the case of FLAMMABLE
REFRIGERANTS, the sensitivity may not be adequate, or may need re-calibration. (Detection equipment
shall be calibrated in a refrigerant-free area.) Ensure that the detector is not a potential source of
ignition and is suitable for the refrigerant used. Leak detection equipment shall be set at a percentage of
the LFL of the refrigerant and shall be calibrated to the refrigerant employed, and the appropriate
percentage of gas (25 % maximum) is confirmed.Leak detection fluids are also suitable for use with most
refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react
with the refrigerant and corrode the copper pipe-work.
Examples of leak detection fluids are:
- bubble method
- fluorescent method agents
If a leak is suspected, all naked flames shall be removed/extinguished.
If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from
the system, or isolated (by means of shutoff valves) in a part of the system remote from the leak.Removal
of refrigerant shall be according to removal and evacuation procedure.
• Removal and evacuation