LG GR-W061BXH handleiding

22 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 9 van 22
Installation
3. Grounding (Earth Ground)
Grounding must be done to prevent electric shock.
Grounded Outlet (earth ground)
connections
• If the 220V outlet has a properly wired ground
connection, no additional grounding is needed.
Connections without Grounded
Outlets (earth ground)
• If a 220V grounded outlet is not available, a
ground wire, connected to a copper plate buried
underground, can be used.
Places where grounding (Earth
Ground) is impossible
• In places where access to ground is not possible,
connect the refrigerator to a leakage protection
switch (rated current 1.10A) and then connect it to
the outlet.
Places where no grounding is allowed
• Never connect ground wires to gas pipes, water
pipes, a lightening arrester, or telephone lines.
4. Please connect with power
supply
Power supply connection
• Plug into a 220V outlet.
5. Storing your wine
• After power is connected, wait 4 hours before placing wine into the refrigerator.
Plastic pipe without conductive properties can not be used for grounding.
9
220 volts AC
grounding line
over
75 cm
leakage
protection
copper plate