Handleiding
Je bekijkt pagina 55 van 67

ENGLISH_index
55
Data 10 (Check Screen)
Data1 00: Check Screen result NG
07: Check Screen result OK
* Sets to NG when Check Screen is set to Off or not supported.
Data 13(For checking Door State)
Data1 Number of the door to check
Data2 00: Closed
01: Opened
Data 15 (when checking the current electric current value)
Data1 Current electric current value in mA
Data 16(For checking Humidity)
Data1 Display the current humidity (%RH) in the Hex value
Data 17(For checking Illuminance)
Data1 Display the current illumination (Lux) in the Hex value
Data 18(For checking the Rotation (Gyro) State)
Data1 00: 0 degrees
01: 90 degrees
02: 180 degrees
03: 270 degrees
Data 09 (In the case of Fan Speed)
Acknowledgement
(v)( )(Set ID)( )(OK/NG)(Data)(Data1)(Data2)(x)
Data1 00-ff: The upper 1-byte of the fan speed
Data2 00-ff: The lower 1-byte of the fan speed
Fan speed: 0 to 2008 in hexadecimal and 0 to 8200 in decimal
* This may not be supported on some models.
52. [Check Screen] (Command: t z)
Sets Check Screen.
Transmission
(t)(z)( )(Set ID)( )(Data)(Cr)
Data 00: Off
01: On
Acknowledgement
(z)( )(Set ID)( )(OK/NG)(Data)(x)
* It may not be supported depending on the model.
53. [Speaker] (Command: d v)
Sets the speaker function.
Transmission
(d)(v)( )(Set ID)( )(Data)(Cr)
Data 00: Off
01: On
Acknowledgement
(v)( )(Set ID)( )(OK/NG)(Data)(x)
* It may not be supported depending on the model.
54. [Daylight Saving Time] (Command: s d)
To set the Daylight Saving Time function.
Transmission
(s)(d)( )(Set ID)( )(Data1)( )(Data2)( )(Data3)( )(Data4)
( )(Data5)(Cr)
Data 00: Off (Data2~5: FFH)
01: Start Time
02: End Time
Data2 01~0C: January to December
Data3 01~06: 1~6th week
* The maximum number of [Data3] differs depending on Date.
Data4 00~06 ( Sun. ~ Sat. )
Data5 00~17: 00~23 hours
* To read the Start Time/End Time, enter FFH for [Data2]~[Data5].
(Example 1: sd 01 01 ff ff ff ff - To check the Start Time)
(Example 2: sd 01 02 ff ff ff ff - To check the End Time)
* This function is supported only when 1 (Year/Month/ Day) and 2 (Hour/
Minute/Second) are set.
Acknowledgement
(d)( )(Set ID)( )(OK/NG)(Data1)(Data2)(Data3)(Data4)
(Data5)(x)
* It may not be supported depending on the model.
Bekijk gratis de handleiding van LG 75XF3ES, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | LG |
| Model | 75XF3ES |
| Categorie | Monitor |
| Taal | Nederlands |
| Grootte | 5526 MB |