3-14
-24 18 12 6 0 6 +12 ovld dB
L
R
Single Setups have only one adjustable parameter on Page 3: OMIX. This
control adjusts the proportion of wet signal to dry signal. Most SINGLE Setup
Presets have OMIX set to WET (100% wet effects). Dual Mono has 2 MIX
parameters; AMIX and BMIX, and Cascade has 3 MIX parameters; AMIX, BMIX,
and OMIX.
Page 4 contains the LFO (Low Frequency Oscillator). The LFO is a control
generator which is designed to modulate patched Effect or Setup parameters.
The LFO has a shape and a rate (speed) function. The shape can be SINEusoidal,
TRIANGLE, SQUARE, or RANDOM. Rate is adjustable from Off to 9.96Hz.
The action of the meters is also determined on this page. The choices are:
For Single Setups:
ANA IN (Analog In) for either Left or Right channel
DIG IN (Digital In) for either Left or Right channel
FX-OUT for either Left or Right channel ( commonly referred to as the
WET BUS)
For Dual-Mono Setups:
L INPUT
R INPUT
L FX OUT (for Mach A)
R FX OUT (for Mach B)
For Cascade Setups:
Input
Mid-Point
Output
Note: If you choose Left Meter or Right Meter as Patch sources when making
MIDI/MOD Patches, you are essentially linking the ballistics of the meter to the
assigned destination.
Page Five is the MIDI/MOD patch page for Setup parameters. As an example,
try patching the LFO to a Balance parameter as follows:
1. Load Setup Preset 1 Large Hall, as described on the previous page.
2. Press PAGE followed by the number 5. The UPPER display should read:
LARGE HALL
SETUP PAGE 5