A NETWORK CONNECTION BETWEEN HOST COMPUTER AND ZONEX PROCESSOR CAN BE CREATED AS FOLLOWS:
A. ROUTER WITH ACTIVATED DHCP SERVER (RECOMMENDED)
When using a router with an enabled DHCP server, the ZoneX processor automatically acquires the IP address during start-up, as soon as the
connection exists. It is recommended to use a router and PoE switch if further control units/controllers from other manufacturers are connected to
the network. This combination provides a DHCP server and also facilitates the power supply for the connected devices. We recommend using Linksys
routers and Netgear switches.
Note: Routers/switches with activated DHCP server should generally be switched on first. And all Ethernet cables should be connected to the
hardware before the devices are switched on. This will allow for a correct IP address assignment.
• First, turn on the router/switch.
• Then connect the host computer to a DHCP enabled router via an Ethernet cable.
• Connect the router to the ZoneX processor via an Ethernet cable.
• Connect the ZoneX processor to the mains and switch it on.
B. NON-DHCP-BASED DIRECT CONNECTION OR INDIRECT CONNECTION VIA ETHERNET SWITCH
If the processor is directly connected to a computer or indirectly via a switch and no DHCP server is available, the connection cannot be established
automatically.
Therefore, non-DHCP-based connections must be configured manually. Further details can be found in the Xilica Designer help file or in the LD
Systems ZoneX FAQ.
BACK
3
POWER CONNECTOR AND FUSE HOLDER
IEC power connector with fuse holder. The packaging content includes a suitable power cable.
CAUTION: Only replace the fuse with another of the same type and with the same ratings. See information on the housing. If the fuse repeatedly
blows, please contact an authorised service centre.
4
ON/OFF SWITCH
Rocker switch to turn the device on and off.
5
ETHERNET - USB - RESET
Communication expansion card with Ethernet connector, or Ethernet + Dante (64 x 64 I/O) on “D” model, for communication between the ZoneX
processor and the host computer, Micro USB recovery port for firmware recovery and IP reset button.
6
REMOTE
LD Systems remote bus for the integration with future control panels and paging microphones from LD Systems. Please note that this connector
only supports LD Systems remote bus-compatible devices and not Ethernet switch ports!
7
GPO
8 GPO outputs (logic ports) with two selectable modes per output: LED (3 mA) or sink (300 mA). 3-pole terminal blocks (pitch 3.81 mm). Please also
note the connection examples in this user manual (see GPI/O – CONNECTION EXAMPLES)
8
GPI
8 GPI inputs (logic ports), with short to ground activation. 3-pole terminal blocks (pitch 3.81 mm). Please also note the connection examples in this
user manual (see GPI/O – CONNECTION EXAMPLES)
9
OUTPUTS
8 balanced audio outputs. 3-pole terminal blocks (pitch 3.81 mm).
10
INPUTS
12 balanced audio mic/line inputs with switchable 48V phantom power per channel. 3-pole terminal blocks (pitch 3.81 mm).
CONNECTING DEVICES
LD Systems ZoneX DSP processor and other control units run on a network-based infrastructure and are configured and controlled via a computer
with the Xilica Designer software.
PREREQUISITES FOR OPERATION
• Computer
• Network interface (router, PoE switch)
A router is required for the IP address assignment and quick and easy connection to your computer and connected control units. A PoE switch is
required for control units without local power supply.
• Ethernet cable. All wired connections use a standard RJ45 Ethernet cable (Cat 5e or better).
4
6
3
7 8 9 10
5
Don‘t connect to any
ethernet switch port!
This port is only for LD
Systems remote bus