LD Systems ADA 12 K4 handleiding
Handleiding
Je bekijkt pagina 11 van 126

11
POWER OFF
From the Power Off page, it is possible to manually put the amplifier in standby mode by clicking the
‘Power OFF’ button. Pushing and holding the rotary encoder for 4s also triggers the standby mode.
The power status LED (4) is green when the amplifier is ON and becomes red when the amplifier is in
standby mode.
Once the amplifier is in standby, to turn it back on, simply touch the screen or push the rotary encoder,
and select ‘Power ON’.
FW UPDATE
Amplifier and Dante firmware updates can be performed via ArmoníaPlus. During the firmware update,
the display will show the message ‘Updating Firmware’, and a status bar will show the progress through
the various phases.
NETWORKING
The ADA Series amplifier supports Dante networking. Dante options are applicable only to 8K4 and 12K4
models. The two-gigabit ports are internally connected via a Gigabit switch to simplify wiring and elimi-
nate the need for external network switches in small systems. Control and Dante audio are available in
both ports by default. This configuration can be checked from the front panel screen under
Node Info > ETH 1/ETH2.
Note: the ADA does not support Dante redundancy, therefore, do never connect the two ethercon ports
to separate primary and secondary Dante networks simultaneously.
IP ADDRESSING
The factory default network configuration is AUTO IP/DHCP.
STATIC IP policy can also be adopted and configured through ArmoníaPlus or the screen panel
(see ‘Net Config’ section).
If a DHCP server is not active in the network, the amplifier platform initiates an auto-configuration with
a local numeric network address (of the type 169.254.X.Y and subnet mask 255.255.0.0).
It is recommended to always turn on the DHCP server before connecting the amplifiers.
ARMONIA PLUS SYSTEM DESIGN
ArmoníaPlus System Manager is the default interface that allows setting and customisation of the
ADA Series amplifiers. Note that whenever the ADA is connected to ArmoníaPlus, the front panel
display operations are disabled.
ArmoníaPlus can be installed on a PC running Windows (XP SP3 and higher).
For a successful connection, both ArmoníaPlus and the ADA Series must belong to the same subnet.
Download ArmoníaPlus System Manager for free from the website:
https://www.powersoft.com/en/software/armoniaplus/
DEUTSCHFRANÇAIS
ESPAÑOL
ENGLISH
ITALIANO POLSKI
Bekijk gratis de handleiding van LD Systems ADA 12 K4, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | LD Systems |
Model | ADA 12 K4 |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 12620 MB |