Lavor Kolumbo handleiding
Handleiding
Je bekijkt pagina 25 van 92

TROUBLES CAUSES SOLUTIONS
1 1 THE GENERATOR 
PRESSURE DOES NOT 
INCREASE
1- Pressure switch
1-Burner
1-Resistance temperature 
detector  PT100
1-Check the pressure 
switch
1-Check electrodes, diesel 
nozzle
1-Check that the tempera
-
ture is at least 150°C
- Authorized After Sales 
Service
- The user
- The user
2 2 THE PUMP CANNOT 
RUN
2.1 It loads no water
2.2 Sound allarm
2.1 The water tank is empty
2.1 Pump
2.1 Clogged lter
2.1 Water level sensors
2.2 Lack of water in the tank
2.2 Check the electronic level
2.2 water solenoid valve
2.1 Fill the tank
2.1 Replace the pump
2.1 Clean the lter
2.1 Clean the water level 
sensors
2.2 Fill the tank
2.2 Replace the solenoid 
valve
2.2 Check and eventually 
replace it
- The user
- Authorized After Sales 
Service
- The user
- The user
- Authorized After Sales 
Service
3 THE SAFETY VALVE 
OPENS REPEATEDLY
3.1 It keeps on     
loading water
3.1Boiler water level probe
3.1Pressure switch
3.1Safety valve
3.1 Clean the water level 
sensors
3.1Replace the pressure 
switch and check that the 
connection discharging 
tube is free from incru
-
stations.
3.1Replace the safety valve
- Authorized After Sales 
Service
- Authorized After Sales 
Service
- Authorized After Sales 
Service
The safety valve can be 
replaced only by or qua
-
lied service center.
Safety valve replacement 
must be set at 12 bar 
and be accompanied 
by certied PED as provi
-
ded for category IV
EN
25
Bekijk gratis de handleiding van Lavor Kolumbo, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Lavor | 
| Model | Kolumbo | 
| Categorie | Stoomreiniger | 
| Taal | Nederlands | 
| Grootte | 12609 MB | 