7.0 Maintenance Continued
7.4 Clean Dump Valve
The dump valve, located on the back of the machine, has a track inside of it. Open the dump
valve and check the track for build-up. This build-up could prevent the dump valve from closing
and cause leaking. Use a toothbrush to clean the track of the dump valve.
7.5 Prevent Mineral Deposit Build-Up
Vinegar may be used to prevent mineral deposit build-up in your machine’s lines and pump.
Failure to do so may clog your lines and pump. Every two weeks, pour vinegar into the solution
tank (dilute with 1/2 water). Run the pump, while squeezing your wand or upholstery tool’s
trigger unit you smell vinegar or notice it coming out of the tool. Let the machine sit overnight,
and no longer, with the vinegar in its lines. The next day, ush the machine with 1-gallon of
clean water or until you do not smell vinegar any longer.
PLEASE NOTE: If you choose to use CLR, follow the directions on the bottle. DO NOT leave CLR in
the machine’s lines and ush thoroughly. CLR may corrode the machine’s components and VOID
your warranty. If you choose to use vinegar, you MUST dilute with 1/2 water. Failure to do so may
damage the machine’s components and VOID your warranty.
7.6 Heater Maintenance
This machine includes a heater system to warm water, similar to a household boiler.
Before using it, the heater and pump must be turned on for at least 5 minutes to
prevent damage. Remember to always turn on the pump when starting the heater.
When the heater is run without the pump, it will overheat causing the elements to
become welded to the inside of the heater tube. This causes water leaks and total
heater failure.
For long-term storage, it’s advised to use antifreeze to maintain the machine.
Antifreeze helps prevent freezing in cold weather and blockages/buildup in warm
weather. This is called “Winterizing” your unit. Left over water within the heater can
freeze. This causes the heater tube to swell and burst, which also causes water leaks
and total heater failure. Check the machine every few months if storing it for long
periods as antifreeze will eventually evaporate and this can cause blockages within the
system. We recommend to change the antifreeze every 2-3 months. Even if you have
winterized your unit - avoid exposing it to extreme temperatures!
7.7 Prevent Clogs & Winterizing Unit
To winterize your unit: Pour antifreeze into the solution tank. For spotters - put a
minimum of two inches of antifreeze in the solution tank. For extractors - remove the
acorn lter and add half a gallon of antifreeze to the solution tank. Then, turn on the
pump and let it run through the system by pressing the trigger of the hand tool or
wand. Excess can be vacuumed out into recovery tank.
If you’re storing the machine for a short period, we still suggest that you winterize or
run water through it regularly to prevent clogs. Clogs are typically not covered under
warranty as they are usually the result of poor maintenance or leaving water in the
tank for extended periods.