(10) Lavex 12-Gallon, 100 PSI Carpet Extractor
5.0 Set-Up and Operation Continued
5.1 Attach the Power Cord
The machines comes with (1) or (2) 25-foot, 12/3-gauge safety power cord(s).
• Locate the pigtail on the back of the machine’s base.
• Plug the lighted end of the power cord into the pigtail.
• Plug the cord into a 20 AMP grounded wall outlet.
• Plug the 2 cords into dierent circuits.
• Make sure there is not something else plug to the same circuit.
• DO NOT plug the cords in a multi-outlet extension cord or portable outlet.
20 AMP circuits are normally found in kitchens and bathrooms. Never remove the ground prong
from the plug. If a circuit breaker trips during operation, turn machine o, reset the breaker and
move the electrical cord to a dierent outlet and resume operation.
5.2 Vacuum System
The extractor uses a dual vacuum motor system that provides outstanding water lift and air ow.
Vacuum Float Assembly Warning System:
The oat assembly shut-o, located in the recovery tank on the vacuum stand pipe, prevents
the waste tank from overowing into the stand pipe and damaging the vacuum motor. The
oat assembly will cut-o vacuum to the waste tank. The motor will also reach a fast, high-
pitched sound alerting you when the recovery tank is about to over ow. When this happens,
immediately turn o the vacuum motor and empty the waste tank. If the operator continues to
use machine after the tank is full, it will VOID the Warranty.
The oat assembly has a lter to prevent debris from entering the stand pipe. Refer to the
“Maintenance” section for removal and proper cleaning. It is also necessary to use low foaming
chemicals or a defoamer to eliminate foam build-up in the recovery tank and damage to the
vacuum motors.
If moisture enters the vacuum motors, contact an authorized service center. To prevent moisture
from damaging the vacuum motors during storage, empty the recovery tank and store with the
lid open.
5.3 Pump System
100 PSI model extractors have self-priming pumps. There is no need to prime this pump.