  KIBXX II/KWIBXX II ICEBERG SERIES SYSTEMS   KWIKOOL 
13 
NOTE 
The condenser fan will not start immediately when the compressor 
operates. Once the condenser fan starts, and if the ambient 
temperature entering the Make-up air for the condenser return is 
below 75 degrees F, the fan may cycle on and off. This is normal. 
  For KIB120XX II models, the fans will instead speedup and 
slowdown in lieu of turning on and off. 
  If the display flashes 99, this indicates ambient 
temperature of 99 degrees F or more. This is normal and 
will stop flashing when the ambient temperature falls below 
99 degrees F. 
3.  FAN - If the Iceberg Series Cooler was previously set to the fan mode then   will be displayed 
and the Supply Air fan will start to run in the selected speed. 
4.  USER OPERATING PARAMETERS LIST- Entrance into this function is gained by a 3-second 
press on the SETTINGS button. Another short press on this button changes the temperature 
display to C or F. Use the FAN and Mode buttons to scroll through the different settings while in the 
“User Parameters”. 
5.  Select ON/OFF to exit or after 1 minute the display will default back to the operating screen. 
6.  ADMINISTRATOR OPERATING PARAMETERS LIST - Entrance into this function is gained by a 
long press of the MODE button until it beeps and flashes a lock icon, then a long press on the FAN 
button until it beeps, then release the FAN button and once again a long press on the FAN button. 
There will be a beep and then display P04. Use the FAN and MODE buttons to scroll through the 
different settings while in the “Administrator Parameters”. 
7.  Select ON/OFF to exit, or after 1 minute the display will default back to the operating screen. 
D  OPERATING PARAMETERS LIST, USER 
P30- Beeper enable 
Select 0 or 1 
0- Disable, 1-enable 
P40-Filter counter 
Hours/10- 0 thru 999 
Read Only 
P41-Filter counter reset 
Select 1 to reset 
Defaults back to 0 
P42-Filter Alarm Delay 
Days, select 0 thru 180 
0- Disable 
P100- Enable Dimming 
Select 0 or 1 
0-Disable, 1 Enable 
P101-Dimming time 
Min, Select 0 through 10 
Defaults to 5 
P102Dimming brightness 
% 1,5,10 through 90 
Defaults to 10 
P105-Brightness in active state 
% 50 through 100 
Defaults to 100 
E  OPERATING PARAMETERS LIST, ADMINISTRATOR 
P04- Lock Fan Button 
Select 0 or 1 
0- Unlock, 1-Lock 
P05- Lock Mode Button 
Select 0 or 1 
0- Unlock, 1- Lock 
P06- Lock On/Off Button 
Select 0 or 1 
0-Unlock, 1- Lock 
P07- Lock Plus/Minus  
Select 0 or 1 
0-Unlock, 1- Lock 