Handleiding
Je bekijkt pagina 12 van 25

KWIKOOL   KIBXX II/KWIBXX II ICEBERG SERIES SYSTEMS   
12 
a)  When changing the set point using a short press on the button, the word SET will appear on the 
display and the current set point flashes on and off. The value of the set point is changed 1 
degree each time the button is pressed. 
b)  The adjusted set point flashes on and off 12 times after the last change and then returns to 
display the room temperature after about ten seconds. 
CAUTION 
Lowering or raising the set point will not change the temperature 
of the Supply Air. For best results always adjust the set point to a 
temperature at which the Iceberg can cycle on and off to avoid 
operational issues such as freezing or rapid discharge air fan 
cycling 
CAUTION 
The lowest set point temperature available for the Iceberg is 60 
degrees F, and the highest set point is 95 degrees F. The control 
will not allow adjustments beyond these ranges. Iceberg systems 
are designed to maintain the set point when sized properly. 
Constant operation without achieving the set point may shorten 
the expected operational life of the system. 
C  SYSTEM OPERATION 
1.  Turn On Iceberg System - Pressing the ON/OFF button once on the control touch screen will allow 
operation of the Iceberg. The system will operate in the previously chosen MODE, either COOL or 
FAN. 
2.  COOL - If the Iceberg Series Cooler was previously set to the cooling mode, then   will be 
displayed. 
a)  If the compressor is running, the  on the display will be flashing. 
b)  If the Iceberg Series System has been sitting for over 2 minutes, this should happen 
immediately upon turning the Iceberg Series System on, unless the set point is lower than the 
current room temperature. In the latter case, the Iceberg Series System is ready to 
automatically turn on once the temperature rises above the set point. 
c)  If the Iceberg Series System was recently turned off or the Iceberg Series System turned itself 
off because it reached the set point, the compressor will not turn on until the system waits for 
approximately 2.5 minutes. This prevents the compressor from being damaged due to a 
condition called short cycling (of the compressor). The indication that the Iceberg Series System 
is in the “time out” condition is that the F (or C) in the display will be flashing. 
d)  When the compressor starts, the F will stop flashing and the  will begin flashing. 