Problem Cause Solution
There is no interior
light on in the
refrigeration unit.
Light switch is in OFF position. Flip switch to ON.
LED board is inoperable. Contact your dealer.
Refrigeration unit is
running noisy.
Soft sounds from compressor, fan motor
& valves.
Normal operation.
Refrigeration unit is
not running correctly.
No power is getting to the unit.
GFI is tripped or the circuit breaker is tripped.
Reset the circuit breaker.
The compartments are
warmer than usual in
the refrigeration unit.
Control preset is not set properly. Reset preset temperature if necessary
Condenser is dirty or obstructed. Clean condenser and clear obstruction.
Door has been left open for an extended
period of time.
Wait 24 hours and recheck temperature.
Internal louvers and/or fan guard obstructed. Ensure louvers and/or fan is not obstructed.
Warm product was placed in the unit. Remove warm product and wait 24 hours.
Refrigeration system
runs for long period
of time.
Condenser is dirty or obstructed. Clean condenser and clear obstruction.
Door has been left open for an extended
period of time.
Wait 24 hours and recheck temperature.
Warm product was placed in the unit. Remove warm product and wait 24 hours.
Hot day and/or warm room temperature. Normal for system to run more frequently.
Condensation forms
on the inside of the
compartments.
High humidity and/or frequent door opening. Normal operation.
Door not closing and sealing properly.
Ensure door is closing properly. Check door
seals and replace if necessary. If condensation
persists, contact your dealer.
Condensation forms
on the outside of the
compartments.
High humidity and/or frequent door opening. Normal operation.
Door not closing and sealing properly.
Make sure door is closing properly. Check door
seals and replace if necessary. If condensation
persists, contact your dealer.
Thermostat ashing
the word “OFF” and
the temperature.
The compressor was turned off.
Hold the power button for 3 seconds and the
compressor will turn back on.
Before calling for service, please use this table to troubleshoot your issue.
Troubleshooting