Maintenance
There is no need to take action when an event occurs
occasionally or only briefly and the device resumes
operation. When an event occurs over long periods or
recurs frequently, the cause must be determined and
rectified.
In case of a permanent event, the inverter interrupts the
feed-in and switches o automatically.
n
Check whether the DC switch or the external DC
voltage separator has been switched o.
n
Check whether the event is due to a mains power
failure, or whether the fuse between the feed meter
and the inverter has tripped.
In case of fuse failure, notify your installer. In the event of
a power failure, wait until the grid operator has rectified
the fault.
If the event lasts only a short time (grid fault, overheating,
overload, etc.), then the inverter will automatically resume
operation as soon as the event has been resolved.
If the event persists, notify your installer or the manufac-
turer's customer support team.
Provide the following information:
n
Device type and serial number. You will find this
information on the type plate on the exterior of the
housing.
n
Error description
(LED display and message in the KOSTAL PIKO CI
app).
DANGER
RISK OF DEATH DUE TO ELECTRI-
CAL SHOCK AND DISCHARGE!
Life-threatening voltages are pres-
ent in the inverter. Only a qualified
electrician may open and perform
work on the device.
INFO
You can find contact details in the
chapter "Warranty and service":
Ch. 10.2
7.7 Event codes