• buffer tank is designed for vertical mounting only (screw feet),
• buffer tank can be installed in the following central heating systems:
- open system, in accordance with legally binding requirements,
- closed system, in accordance with legally binding requirements,
• buffer tank must be mounted in the place and in such a way to avoid room flooding
caused be leaking tank or connectors.
Installation
Check out the pipe connections and make sure that you observe the connection diagrams
before start-up.
Check out for water leaks. Check out the safety valve performance in accordance to
valve manufacturer’s instruction.
Start -up
Dimensions
Modell
SV
200.1
SVW
200.1
SV
300.2
SVW
300.2
SV
400.1
SVW
400.1
SV
500.1
SVW
500.1
SV
800.1
SVW
800.1
SV
1000.1
SVW
1000.1
D
mm
595 692 755 854 994 994
d 457 550 600 650 790 790
H 1616 1596 1643 1761 1911 2241
A 266 249 256 261 294 294
B 618 611 626 656 718 828
C 970 973 996 1051 1142 1362
E 1322 1338 1368 1446 1566 1895
F 125 126 124 130 160 160
G 554 544 550 629 691 801
I 911 940 947 1064 1099 1379
J 1239 1249 1278 1379 1539 1869
K 1700 1740 1810 1975 2130 2430
K’ - - 1675 1800 1915 2245
L - 256 - 239 - 246 - 251 - 293 - 293
N - 811 - 850 - 856 - 974 - 1182 - 1294