Handleiding
Je bekijkt pagina 14 van 68

14
Pipe Length and Additional Refrigerant
Inverter Models
Capacity (Btu/h)
9K-12K
18K-36K
Length of pipe with
standard charge
5m/16ft
5m/16ft
5m/16ft
5m/16ft
Length of pipe with
standard charge (Like:
North American, etc.)
7.5m/24ft
7.5m/24ft
7.5m/24ft
7.5m/24ft
Maximum distance
between indoor and
outdoor unit
15m/49ft
15m/49ft
20m/65ft
30m/98ft
Additional refrigerant
charge
20g/m
15g/m
30g/m
25g/m
Max. diff. in level
between indoor and
outdoor unit
10m/32ft
10m/32ft
15m/48ft
20m/65ft
Type of refrigerant
R22/R410A
R32
R22/R410A
R32
ON-OFF Models
Capacity (Btu/h)
9K-12K
18K-36K
Length of pipe with
standard charge
5m/16ft
5m/16ft
5m/16ft
5m/16ft
Maximum distance
between indoor and
outdoor unit
15m/49ft
15m/49ft
15m/49ft
15m/49ft
Additional refrigerant
charge
20g/m
15g/m
30g/m
25g/m
Max. diff. in level between
indoor and outdoor unit
5m/32ft
5m/32ft
5m/32ft
5m/32ft
Type of refrigerant
R22/R410A
R32
R22/R410A
R32
Torque Parameters
PIPE Size
Newton meter [N x
m]
Pound-force foot
(Ibf-ft)
Kilogram-force meter
(kgf-m)
1/4 (ø6.35)
15 - 20
11.1 - 14.8
1.5 2.0
3/8 (ø9.52
31 - 35
22.9 25.8
3.2 3.6
1/2 (ø12)
45 - 50
33.2 36.9
4.6 5.1
5/8 (ø 15.88)
60 - 65
44.3 48.0
6.1 6.6