Problem Possible Causes
The appliance does
not operate.
Power failure/plug pulled out.
Damaged indoor/outdoor unit fan motor.
Faulty compressor thermomagnetic circuit breaker.
Faulty compressor thermomagnetic circuit breaker.
Loose connections or plug pulled out.
It sometimes stops operating to protect the appliance.
Voltage higher or lower than the voltage range.
Active TIMER-ON function.
Damaged electronic control board.
Strange odour. Dirty air filter.
Noise of running water. Back flow of liquid in the refrigerant circulation.
A fine mist comes from
the air outlet.
This occurs when the air in the room becomes very cold, for
example in the ‘COOL’ or ‘DEHUMIDIFYING/DRY’ modes.
A strange noise can be
heard.
This noise is made by the expansion or contraction of the
front panel due to variations in temperature and does not
indicate a problem.
Insufficient airflow,
either hot or cold.
Unsuitable temperature setting.
Obstructed air conditioner intakes and outlets.
Dirty air filter.
Fan speed set at minimum.
Other sources of heat in the room.
No refrigerant.
The appliance does
not respond to
commands.
Remote control is not close enough to indoor unit.
The batteries of remote control need to be replaced.
Obstacles between remote control and signal receiver in
indoor unit.
The display is off.
Active DISPLAY function.
Power failure.