Inspections Before Test Run
Description Inspection method
Electrical safety
inspection
Check whether the power supply voltage complies with
specification.
Check whether there is any wrong or missing connection
between the power lines, signal line and earth wires.
Check whether the earth resistance and insulation resistance
comply with requirements.
Installation
safety inspection
Confirm the direction and smoothness of drainage pipe.
Confirm that the joint of refrigerant pipe is installed completely.
Confirm the safety of outdoor unit, mounting plate and indoor
unit installation.
Confirm that the valves are fully open.
Confirm that there are no foreign objects or tools left inside the
unit.
Complete installation of indoor unit air inlet grill and panel.
Refrigerant
leakage
detection
The piping joint, the connector of the two valves of the outdoor
unit, the valve spool, the welding port, etc., where leakage may
occur.
Foam detection method: Apply soapy water or foam evenly on
the parts where leakage may occur and observe whether
bubbles appear or not, if not, it indicates that the leakage
detection result is safe.
Leak detector method: Use a professional leak detector and
read the instruction of operation, detect at the position where
leakage may occur.
The duration of leak detection for each position should last for 3
minutes or more.
If the test result shows that there is leakage, the nut should be
tightened and tested again until there is no leakage.
After the leak detection is completed, wrap the exposed pipe
connector of indoor unit with thermal insulation material and
wrap with insulation tape.