No ignition sources:
No person carrying out work in relation to a refrigeration system which involves exposing any
pipe work shall use any sources of ignition in such a manner that it may lead to the risk of
fire or explosion. All possible ignition sources, including cigarette smoking, should be kept
sufficiently far away from the site of installation, repairing, removing and disposal, during
which refrigerant can possibly be released to the surrounding space. Prior to work taking
place, the area around the equipment is to be surveyed to make sure that there are no
flammable hazards or ignition risks. No Smokingsigns shall be displayed.
Ventilated area:
Ensure that the area is in the open or that it is adequately ventilated before breaking
into the system or conducting. A degree of ventilation shall continue during the period
that the work is carried out.
The ventilation should safely disperse any released refrigerant and preferably expel it
externally into the atmosphere.
Checks to the refrigeration equipment:
Where electrical components are being changed, they shall be fit for the purpose and
to the correct specification. At all times, the maintenance and service guidelines shall
be followed.
If in doubt, contact help.Kogan.com for support.
The following checks shall be applied to installations using flammable refrigerants:
o The charge size is in accordance with the room size within which the
refrigerant containing parts are installed.
o The ventilation machinery and outlets are operating adequately and are not
obstructed.
o If an indirect refrigerating circuit is being used, the secondary circuit shall be
checked for the presence of refrigerant.
o Marking to the equipment continues to be visible and legible. Markings and
signs that are illegible shall be corrected.
o Refrigeration pipe or components are installed in a position where they are
unlikely to be exposed to any substance which may corrode refrigerant
containing components, unless the components are constructed of materials
which are inherently resistant to being corroded or are suitably protected
against being so corroded.