To avoid accidental contact with the overheated bottom of the cooktop or unexpected
electrical shocks during operation, it is necessary to install a wooden insert. This insert
should be fixed with screws at a minimum distance of 50mm from the bottom of the
cooktop. Follow the requirements outlined below.
Warning:
There are ventilation holes around the perimeter of the cooktop. You must ensure these
holes are not blocked by the worktop when installing the cooktop.
The glue used to bond plastic or wooden materials to the cabinetry must withstand
temperatures of at least 150°C to prevent the panels from detaching.
The rear wall and adjacent surfaces must be capable of withstanding temperatures up
to 90°C.
After Installation
After installing the cooktop, ensure that:
The power cord is not accessible through cupboard doors or drawers.
There is adequate airflow of fresh air from outside the cabinetry to the base of the
cooktop.
If the cooktop is installed above a drawer or cupboard space, a thermal protection
barrier is installed below the base of the cooktop.
The isolating switch is easily accessible to the user.
Before Locating the Fixing Brackets
The cooktop should be placed on a stable, smooth surface (use the packaging). Do not
apply force onto the controls protruding from the cooktop.