Adjusting the Minimum Level of the Flame:
1. Turn the taps down to the minimum.
2. Remove the control knob from the tap and place a small, bladed screwdriver in the
centre of the adjustment screw.
3. The correct adjustment is obtained when the flame has a length of about 3-4 mm.
For butane/ propane gas, the adjusting screw must be tightly screwed in.
4. Refit the control knob. Make sure that the flame does not go out by quickly turning
from maximum flow to minimum flow. If it does, then remove the control knob and
make further adjustments to the gas flow, testing it again once the adjustment
has been made.
5. Repeat this process for each of the taps.
Caution:
Do not dismantle the tap safe. In the event of a malfunction, change the whole tap.
Before replacing the burners, ensure the injector is not blocked.
A full operational test and a test for possible leakages must be carried out after gas
conversion, (such as with soapy water or a gas detector).
After completing conversion, a qualified technician must mark ‘V’ on the right gas
category to match with the setting on the rating plate. Remove the previous setting ‘V’
mark.
Control knob
Tap
Sealing ring
Adjustment screw