19
Gas Connection
Install in accordance with relevant gas standards and/or codes. Connect the elbow
fitting to the appliance gas manifold connection and check that the seals between the
elbow and manifold connection are in place and in good condition.
For Natural Gas:
o Connect the natural gas appliance regulator (pictured below) with integral
test point using approved gas thread tape or compound to the elbow fitting.
o Ensure the supply connection point, test point and natural gas regulator
adjustment screw are accessible for testing and/or adjustment with the
hotplate in the installed position.
For Universal LPG: Connect the brass test point adaptor (pictured below) using
approved gas thread tape or compound to the elbow fitting.
Natural Gas Regulator Brass Test Point Adaptor
Where a flexible hose assembly is used, ensure it is approved to AS/NZS 1869, Class B.
The hose assembly must be restrained from accidental contact with the flue outlet of
an under-bench oven. It must be suitable for connection to a fixed consumer piping
outlet located as follows: for hotplates, at a point 800mm to 850mm above the floor
and within a region extending 250mm beyond the width of the appliance.
After connecting to gas, check for leaks using soapy solution, never a naked flame.
50
800
250
250
Width of
appliance