Electrical connection
All electrical work must be carried out by a suitably qualied and authorized
electrician. No alterations or willful changes in the electricity supply should be
carried out.
Before attempting the connection, check whether the voltage indicated on the
rating plate corresponds to the actual mains voltage.
Mains lead should be minimum1. 5m long.
Earthing wire should be installed in such manner to be the last one pulled
out in case the safety relief device of the mains lead should fail.
Mains lead behind the oven must be placed in such manner to avoid touching
the back panel of the oven because of the heat it develops during operation.
The cable of correct size rating must be used cable type HO5VV-F 3× 1.5. m
2
.
the grounding wire shall belonger than the other wires.
The means for disconnection from the supply mains having a contact
separation in all poles that provide full disconnection under over voltage xed
wiring in accordance with the wiring rules.
Connection (by authorised electrician)
Using the screwdriver open the connector cover at the rear of the appliance.
Release two locks located at either side of the connector bottom.
Mains lead must be led through the relief safety device, protecting the mains
lead cable from disconnection.
Tighten the relief device securely and close the connector cover.
-
zzzz
Colour codes
L = LIVE, coloured brown or black.
N = NEUTRAL, coloured blue or white.
Beware of the correct N-connection!
EARTH = coloured green or yellow green.