SAFETY PRECAUTIOS ON SERVICING
Please follow these warnings when to undertake the following when servicing a
dehumidier with R290.
1 Checks to the area
Prior to beginning work on systems containing ammable refrigerants, safety
checks are necessary to ensure that the risk of ignition is minimized. For repair to
the refrigerating system, the following precautions shall be complied with prior to
conducting work on the system.
2 Work procedure
Work shall be undertaken under a controlled procedure so as to minimize the risk
of a ammable gas or vapor being present while the work is being performed.
3 General work area
All maintenance staff and others working in the local area shall be instructed on
the nature of work being carried out. Work in conned spaces shall be avoided.
The area around the workspace shall be sectioned off. Ensure that the conditions
within the area have been made safe by control of ammable material.
4 Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to
and during work, to ensure the technician is aware of potentially ammable
atmospheres. Ensure that the leak detection equipment being used is suitable for
use with ammable refrigerants, i.e. no sparking, adequately sealed or intrinsically
safe.
5 Presence of re extinguisher
If any hot work is to be conducted on the refrigeration equipment or any
associated parts, appropriate re extinguishing equipment shall be available to
hand. Have a dry powder or CO
2
re extinguisher adjacent to the charging area.
6 No ignition sources
No person carrying out work in relation to a refrigeration system which involves
exposing any pipe work that contains or has contained ammable refrigerant
shall use any sources of ignition in such a manner that it may lead to the risk of
re or explosion. All possible ignition sources, including cigarette smoking, should
be kept suciently far away from the site of installation, repairing, removing and
disposal, during which ammable refrigerant can possibly be released to the
surrounding space. Prior to work taking place, the area around the equipment is
to be surveyed to make sure that there are no ammable hazards or ignition risks.
“No Smoking” signs shall be displayed.
7 Ventilated area
Ensure that the area is in the open or that it is adequately ventilated before
breaking into the system or conducting any hot work. A degree of ventilation shall
continue during the period that the work is carried out. The ventilation should
Bekijk gratis de handleiding van Klarstein DryFy Grand Smart 55, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.