14
If the water pressure to the reverse osmosis system is less than
40 psi to 60 psi (276 kPa to 414 kPa):
Check to see whether the sediment filter in the reverse
osmosis system is blocked. Replace the filter if necessary.
Allow the storage tank on the reverse osmosis system to refill
after heavy usage.
If you have questions about your water pressure, call a licensed,
qualified plumber.
Connect Water Supply
Read all directions before you begin.
IMPORTANT:
Connect to potable water only.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts.
Plumbing shall be installed in accordance with the
International Plumbing Code and any local codes and
ordinances.
Use copper tubing or supply line, and check for leaks.
Install tubing only in areas where temperatures will remain
above freezing.
Tools Needed:
Gather the required tools and parts before starting installation.
Flat-blade screwdriver
7/16" and 1/2" open-end wrenches or two adjustable wrenches
1/4" nut driver
NOTE: Do not use a piercing-type or 3/16" (4.76 mm) saddle
valve which reduces water flow and clogs more easily.
Connecting the Water Line
1. Turn off main water supply. Turn on nearest faucet long
enough to clear line of water.
2. Using a 1/2" copper supply line with a quarter-turn shutoff
valve or the equivalent, connect the ice maker as shown.
NOTE: To allow sufficient water flow to the ice maker, a
minimum 1/2" diameter home supply line is recommended.
A. Bulb
B. Nut
3. Now you are ready to connect the copper tubing. Use 1/4"
(6.35 mm) O.D. soft copper tubing for the cold water supply.
Ensure that you have the proper length needed for the job.
Be sure both ends of the copper tubing are cut square.
Slip compression sleeve and compression nut on copper
tubing as shown. Insert end of tubing into outlet end
squarely as far as it will go. Screw compression nut onto
outlet end with adjustable wrench. Do not overtighten.
For custom panel installation, be sure the water line
extends 30ʺ (762 mm) beyond the cabinet for future
servicing purposes.
A. Compression
sleeve
B. Compression nut
C. Copper tubing
4. Place the free end of the tubing into a container or sink, turn
on main water supply, and flush out tubing until water is clear.
Turn off shutoff valve on the water pipe.
IMPORTANT: Always drain the water line before making the
final connection to the inlet of the water valve to avoid possible
water valve malfunction.
5. Bend the copper tubing to meet the water line inlet. The water
inlet tube is located on the back of the ice maker cabinet as
shown in “Rear View” illustration. Leave a coil of copper tubing
to allow the ice maker to be pulled out of the cabinet or away
from the wall for service.
Rear View
A. Copper tubing
B. Water supply
tube clamp
C. Inlet water tube clamp and
supply line connector for
standard model
D. Inlet water tube for custom
panel model
6. Remove and discard the short plastic tube from the end of the
water line inlet.