6
2. Other Alarm Visual And Audible Indicators
Operational Mode Visual Indications Audible Indications Action / Note
Normal (standby) AC power: Green LED on
continuously.
DC power: Green LED blinks
approx every 60 sec.
Test (Test/Hush button
press, or remote Test
using app, when no
alarm condition is
present) (Note: Test is
very loud, stand a few
feet away.)
Red LED blinks in time with
alarm pattern.
Smoke Models:
Single beep.
3 long beeps, pause, 3 long beeps.
Combination Smoke/CO Models:
Single beep.
• 3 long beeps, voice “Fire!,” 3
long beeps, 4 quick beeps, voice
Warning, Carbon Monoxide,” 4
quick beeps.
Perform test once per week to
verify proper alarm operation.
Smoke or CO Alarm
Memory (unit has
experienced a smoke or CO
alarm event, or has detected
100ppm CO or greater.) (CO
only on combination smoke/
CO models)
Smoke: Red LED blinks every
15 sec.
CO (combination smoke/CO
models only): 2 red LED blinks
every 15 sec.
After Test/Hush button push,
voice “Smoke
previously detected” or “Carbon
monoxide previously detected.”
(Voice only on combination
smoke/CO models)
NOTE: Alarm memory is only
retained for 24 hrs.
Push Test/Hush button to clear
Alarm Memory.
Smoke Alarm HUS
Mode
Red LED blinks every 2 sec.
(only on the initiating alarm)
After Test/Hush button push, or
remote Hush using app, voice
“Hush Mode Activated.” Smoke
alarm pattern stops. If there is
too much smoke to allow HUSH,
voice “Too much smoke, alarm
cannot be hushed.” (smoke alarm
pattern continues) (Voice only on
combination smoke/CO models)
This feature is to be used only
when a known alarm condition,
such as smoke from cooking,
activates the alarm. Push Test/
Hush button or remote SMART
HUSH® using the app again
during HUSH to clear HUSH
and
perform a test.
CO Alarm Reset
(combination smoke/CO
models only)
None After Test/Hush button push, or
remote Reset on the app, CO
alarm pattern stops.
Unit is confirming if CO is present
or if it experienced a nuisance
situation. Re-alarm means danger.
Exit to fresh air and call 911.
Initiating Alarm
(Multiple Alarms In An
Interconnected System)
Red LED blinks in time with
alarm pattern indicating that this
is the unit initiating the alarm
in an interconnected, multiple
alarm, system.
NOTE: It is possible for more
than one unit to detect a hazard
and become an initiating alarm
unit (Red LED blinking).
Unit in either Smoke or CO alarm
mode.